| Serial Number | Area Name |
|---|---|
| 1, 2, 3 | Alarm indicator light window |
| 4 | Left click |
| 5 | Middle button |
| 6 | Right-click |
| 7 | Gas sensing hole |
| 8 | Charging port |
| 9 | LCD screen |
The main components are the shell, circuit board, battery, display screen, sensor, and charger.
Electrochemical type and catalytic combustion type.
| Standard Gas Detection Range | EX or CO or H2S or CO2 (for other detectable gases, see the attached table) |
|---|---|
| Display Error | EX≤5%FS, CO: ±5umol/mol or ±10%, H2S: ±2umol/mol or ±10%, O2: ±0.7%VOL |
| Response Time | T90≤30s(EX), T90≤60s(CO), T90≤60s(H2S), T90≤20s(O2) |
| Display Method | LCD shows real-time data and system status; LED, sound, vibration indicator alarm, fault and undervoltage |
| Working Environment | Temperature -20℃~50℃; Humidity <95% RH (no condensation) |
| Operating Voltage | DC3.7V (Lithium battery capacity 2000mAh) |
| Explosion-proof Mark | Ex ib IIB T3 Gb |
| Charging Time | 6h ~ 8h |
| Standby Time | Greater than 8 hours |
| Sensor Life | 2 years |
| Dimensions | 112 * 56 * 45 (mm) (including back clip) |
| Weight | Approximately 152g |
The detector should be stored in a ventilated room with an ambient temperature of -10℃ to 55℃ and a relative humidity not exceeding 85%RH. The air should not contain harmful gases or impurities that could corrode the detector.
The supporting detection instrument includes one packing box, one portable single gas detector, one charger, one manual, and one warranty card with a certificate of conformity.
Custom instruments can be configured to detect gases listed in the table below:
| Detecting Gas | Normal Range | Selectable Range | Resolution | Low Alarm | High Alarm |
|---|---|---|---|---|---|
| Oxygen | 0~30%VOL | 0~30%VOL | 0.1 %VOL | 19.5 | 23.5 |
| Methane | 0~4%VOL | 0~4%VOL | 0.01 %VOL | 1.00 | 2.50 |
| Carbon monoxide | 0~1000PPM | 0~2000/ 5000PPM | 1 PPM | 50 | 200 |
| Hydrogen sulfide | 0~100PPM | 0~50/200/1000PPM | 1/0.1PPM | 10 | 20 |
| Flammable gas | 0~100%LEL | 0~100%LEL | 1%LEL | 20 | 50 |
| Ammonia | 0~100PPM | 050/500/1000PPM | 1/0.1PPM | 20 | 50 |
| Hydrogen gas | 0~1000PPM | 0~40000PPM | 1/0.1PPM | 200 | 500 |
| Chlorine gas | 0~20PPM | 0~100/1 50PPM | 1/0.1 PPM | 5 | 10 |
| Hydrogen chloride | 0~20PPM | 0~20/ 150PPM | 1/0.1PPM | 5 | 10 |
| Sulfur dioxide | 0~20PPM | 0~50/ 100PPM | 1/0.1PPM | 5 | 10 |
| Nitric oxide | 0~250PPM | 0~500/ 1000PPM | 1/0.1PPM | 20 | 125 |
| Nitrogen dioxide | 0~20PPM | 0~50PPM | 1/0.1 PPM | 5 | 10 |
| Carbon dioxide | 0~5000PPM | 0- 5%/10%VOL (Infrared) | 1PPM/0.1%VOL | 1000/0.2 | 2000/0.5 |
| Phosphine | 0~20PPM | 0~20PPM | 1PPM | 5 | 10 |
| Hydrogen chloride | 0~20PPM | 0~20PPM | 1PPM | 10 | 25 |
| Epoxy ethane | 0~100PPM | 0~100PPM | 1PPM | 20 | 50 |
| Ethylene oxide | 0~100PPM | 0~100PPM | 1PPM | 20 | 50 |
| Ozone | 0~100PPM | 0~100PPM | 1PPM | 20 | 50 |
| Formaldehyde | 0~40PPM | 0~50/100PPM | 1/0.1PPM | 8 | 20 |
| Benzene | 0~1000PPM | 0~1000PPM | 1PPM | 200 | 500 |
| Toluene | 0~1000PPM | 0~1000PPM | 1PPM | 200 | 500 |
| Xylene | 0~1000PPM | 0~1000PPM | 1PPM | 200 | 500 |
| VOC | 0~1000PPM | 0~1000PPM | 1PPM | 200 | 500 |
| Vinyl chloride | 0~250PPM | 0~250PPM | 1PPM | 50 | 125 |
| Methanol | 0~30PPM | 0~30PPM | 1PPM | 6 | 15 |
| Isobutene | 0~90PPM | 0~90PPM | 1PPM | 18 | 45 |
| Ethanol | 0~80PPM | 0~80PPM | 1PPM | 16 | 40 |
| Arsine | 0-10PPM | 0-10PPM | 0.1PPM/0.01PPM | 2 | 5 |
The detector utilizes electrochemical type and catalytic combustion type principles depending on the installed sensor type.
To ensure high detection accuracy, the device should be calibrated regularly, with the calibration interval not exceeding one year.
The detector runs on a DC3.7V lithium battery with a capacity of 2000mAh, offering a standby time of more than 8 hours and a charging time of 6 to 8 hours.
The detector should be stored in a well-ventilated room at temperatures between -10℃ and 55℃, with relative humidity not exceeding 85%RH, free from corrosive gases or impurities.
No. You must not disassemble, replace, or charge the battery pack in explosive gas environments. Replacing sensors or using plug-in devices without explosion-proof certification in such environments is strictly prohibited.
The standard kit includes one packing box, one portable single gas detector, one charger, one user manual, and one warranty card complete with a certificate of conformity.