High-Quality Portable Gas Detector Pen Shield JLY-50A Series Manufacturer, Manufacturers

Product Overview

 

The JYL-50A portable gas detector (hereinafter referred to as the detector) adopts advanced large-scale integrated circuit technology, international standard intelligent design technology, and proprietary digital-analog hybrid communication technology to design a fully intelligent gas detector. The detector uses a free diffusion method to detect gases, with high-quality gas sensors as the sensitive components, offering excellent sensitivity and outstanding repeatability. It is easy to use and maintain, meeting the reliability requirements of industrial site safety monitoring. The casing is made of high-strength engineering plastic, which is strong, has a good feel, and is waterproof, dustproof, and explosion-proof.

 

Application

 

This detector is widely used in industries such as petroleum, chemical, environmental protection, metallurgy, refining, gas distribution, biochemical medicine, and agriculture. The design, manufacture, and inspection of this product comply with the following national standards.

Product Description

Alarm situation-4
Combustible Gas Leak Detector - Alarm & Functions
Size-1
Leak Detector Structure & Dimensions
Special Functions
  • Powered by 3V batteries (two AA batteries)
  • Sensor unit with built-in temperature compensation & calibration coefficients for high precision, good linearity, stability, and fast recovery
  • LCD displays gas concentration with two-pole alarm color prompts
  • Simple calibration, automatic verification, zeroing, and automatic compensation programs
  • Anti-radiation & electromagnetic interference design to minimize false alarms
  • Buzzer alarm indicating two levels of concentration alarm
  • LCD battery status indicator for timely battery replacement
  • Miniaturized, economical, and practical design for convenient operation and maintenance
Structure & Working Principle
Leak Detector Structure
The device mainly consists of components such as the casing, circuit board, battery, display screen, and sensors.
Working Principle
Catalytic combustion type.
Technical Parameters
Parameter Specification
Measure gasFlammable EX (calibrated with methane CH4)
Measurement range0~10000PPM
Preheating time<1 minute
Response time≤30 seconds
Indication modeLCD screen displays power supply, concentration, alarm information and sound alarm
Shell materialABS
Explosion-proof markExib IIB T3 Gb
Alarm thresholdUnderreporting: approx. 2000PPM;High report: Approx. 4000PPM
Sensor lifespanFive years
Sensor driftEvery half a year;Zero point <2%FS, sensitivity <3%FS
Working environment-10~55°C; <95%RH
Battery voltageDC 3V (two replaceable AA batteries)
Equipment size162*25*21mm
Standby timeAbout 2 hours
Equipment weightAbout 38 grams
Storage & Accessories
Storage Conditions
The detector should be stored in a ventilated room with an ambient temperature of -10°C to 55°C and a relative humidity not exceeding 85%RH. The air should not contain harmful gases or impurities that could corrode the detector.
Standard Accessories
  • One combustible gas leak detector
  • Two No. 7 batteries
  • One instruction manual
Appendix: Detectable Gases Range
Detecting Gas Normal Range Selectable Range Resolution Low Alarm High Alarm
Oxygen0-30%VOL0-30%VOL0.1%VOL19.523.5
Methane0-4%VOL0-4%VOL0.01%VOL12.5
Carbon monoxide0-1000PPM0-2000/5000PPM1PPM50200
Hydrogen sulfide0-100PPM0-50/200/1000PPM1/0.1PPM1020
Flammable gas0-100%LEL0-100%LEL1%LEL2050
Ammonia0-100PPM0-50/500/1000PPM1/0.1PPM2050
Hydrogen gas0-1000PPM0-40000PPM1/0.1PPM200500
Chlorine gas0-20PPM0-100/150PPM1/0.1PPM510
Hydrogen chloride0-20PPM0-20/150PPM1/0.1PPM510
Sulfur dioxide0-20PPM0-50/100PPM1/0.1PPM510
Nitric oxide0-250PPM0-500/1000PPM1/0.1PPM20125
Phosphine0-20PPM0-20PPM1PPM510
Hydrogen cyanide0-20PPM0-20PPM1PPM1025
Acetylene0-100PPM0-100PPM1PPM2050
Ethylene oxide0-100PPM0-100PPM1PPM2050
Ozone0-100PPM0-20/100PPM0.1PPM2050
Formaldehyde0-40PPM0-50/100PPM1/0.1PPM820
Benzene0-1000PPM0-1000PPM1PPM200500
Toluene0-1000PPM0-1000PPM1PPM200500
Xylene0-1000PPM0-1000PPM1PPM200500
VOC0-1000PPM0-1000PPM1PPM200500
Vinyl chloride0-250PPM0-250PPM1PPM50125
Methanol0-30PPM0-30PPM1PPM615
Isobutene0-90PPM0-90PPM1PPM1845
Ethanol0-80PPM0-80PPM1PPM1640
Note: The detection range of customized instruments is subject to the actual instruments delivered. For gases not listed, please contact the manufacturer.
Frequently Asked Questions (FAQ)
What type of battery does this gas leak detector require?
The detector is powered by DC 3V using two replaceable AA batteries.
What is the sensor lifespan and response time?
The sensor has a lifespan of five years and features a quick response time of ≤30 seconds.
How does the alarm system alert users of a gas leak?
It uses a dual alert system: the LCD screen provides two-pole color prompts displaying concentration levels, accompanied by a two-level buzzer sound alarm.
What environment conditions are suitable for operation and storage?
The device operates in temperatures from -10°C to 55°C with relative humidity below 95%RH. Storage requires a ventilated room within the same temperature range and humidity under 85%RH.
Can this detector be customized for gases other than Methane?
Yes, custom instruments can be configured to detect a wide variety of gases such as Oxygen, Carbon Monoxide, Hydrogen Sulfide, Ammonia, VOCs, and more as detailed in the appendix.
What is the working principle of this detector?
The leak detector operates using catalytic combustion technology for reliable and linear gas concentration measurement.