Ensure no scratches on the appearance of the product, the label is complete and clear, and all accessories are complete.
| Detecting gas | Methane / propane / other gases |
| Detection Principle | Catalytic Combustion / Infrared / Electrochemical / Semiconductor / PID |
| Sampling method | Diffusion |
| Measuring range | (3~ 100)%LEL or others |
| Alarm setpoint (default for combustible gases) | 25% LEL low limit / 50% LEL high limit |
| Alarm error | ±3%F.S |
| Response time | Combustible gas ≤30S(T90) / toxic gas ≤60S(T90) |
| Power consumption | ≤3W (DC24V) |
| Protection class | IP66 |
| Explosion-proof grade | ExdⅡCT6Gb |
| Communication mode | S-BUS bus & 4-20mA wiring system |
| External control output | 1 passive switch signal, contact capacity 1A/AC220V or 1A/DC24V |
| Sensor life | Three years (catalytic typical) |
| Storage Temperature | -25℃ ~ +55℃ |
| Use environment | Temperature -40℃ ~ +70℃, relative humidity ≤93%RH |
| Explosion-proof cable introduction interface | Wire outer diameter 9-10mm |
| Threaded connection size | G3/4 |
| Product weight | About 880g |
| Product size | 156.5mm x 150.5mm x 76.5mm |
| Display Status | Status Description |
|---|---|
| — | Equipment self-test |
| [Blank] | Equipment failure |
| -E1- | Sensor failure |
| -E2- | Sensor anomaly |
To ensure that you fully understand the characteristics, functions and operating requirements of the product, so as to avoid any unnecessary damage or accidents. Before using the product, please be sure to read and understand the contents of this manual completely, especially the warnings and precautions, and keep this manual appropriately.
Distress & Critical Precautions
Operation Warnings
General Safety Precautions